RAD Ducted Heat Pumps

RAD Ducted Heat Pumps_header

RAD Ducted Heat Pumps

Discreet air conditioning for the home or business. Ducted systems provide discreet air conditioning that doesn’t occupy valuable wall space and air diffusers can be positioned to fit around lighting and other fixtures. The heat pump system delivers low-energy heating by utilising it's high efficiency inverter compressor technology. When only a small amount of heating or cooling is required it reduces energy input to save power.
RAD Ducted Heat Pumps_0

Discreet Concealed Installation

The ducted unit is designed to fit into ceiling spaces where it supplies conditioned air through ducting to required rooms.

Ducted systems provide discreet air conditioning that doesn’t occupy valuable wall space and air diffusers can be positioned to fit around lighting and other fixtures.

Energy Efficient Comfort

RAD Ducted Heat Pumps_1
RAD Ducted Heat Pumps_2

Whisper Quiet

Ducted systems are one of the quietest types of air conditioning with installed sound levels quieter than an equivalent capacity wall mounted heat pump.
RAD Ducted Heat Pumps_3

Industry Leading Warranty

An industry leading 6 year parts and labour warranty covers the Hitachi wall split air conditioning for your home and office. This offers peace of mind that your heat pump will perform year after year.
RAD Ducted Heat Pumps_4

Advanced Wall Control

The SPX-WKT3 wall controller offers the latest in advanced comfort and convenience control.

- Track power consumption
- 24/7 programmable timer
- Eco mode
- Sleep mode
- Powerful mode
- Leave home function
RAD Ducted Heat Pumps_5

Rapid Heating & Cooling in any Weather

Powerful Mode will run your system at maximum output for 20-minutes projecting airflow further and faster to cool or heat a room rapidly.

RAD ducted systems can operate in outside temperatures down to as low as -15˚C and as high as 46˚C ensuring you always stay comfortable.
RAD Ducted Heat Pumps_6

Energy Saving Features

At the push of a button, Eco Mode efficiently delivers a slightly reduced temperature to help keep energy consumption to a minimum.

Hitachi RAD Series have Ultra Low Standby Power to further increase energy efficiency.
RAD Ducted Heat Pumps_7

Wifi Control for your Hitachi Ducted Heat Pump.

Installing the optional airCloud Go wifi controller module will allow you to control your Ducted Heat Pump using a smartphone or tablet.

Operate your Ducted Heat Pump from home or remotely, adjusting temperature, fan speed and setting custom schedules. airCloud is also compatible with Google Alexa and Amazon Echo smart speakers, so you can operate your Ducted Heat Pump using voice commands.

Further information on the airCloud Go can be found here.

Model

Model

RAD/RAC-E50YHA RAD/RAC-E60YHA RAD/RAC-E70YHA
Capacity Nominal Cooling kW
Nominal Heating kW
Capacity (Range) Cooling kW
Heating kW
Airflow (Hi/Med/Low/S low) l/sec
External static Pa
Energy Efficiency EER / AEER Cooling
COP / ACOP Heating
Noise Levels (dB(A)) Cooling Indoor Unit Hi/Med/Low/S low
Outdoor Unit Cooling/Heat/ Night
Dimensions (mm) Indoor Unit (WxHxD)
Outdoor Unit (WxHxD)
Indoor unit seperable
Weights (kg) Indoor / Outdoor
Air Spigot/ Drain Dimensions Supply Air (W X H mm)
Return Air (W X H mm)
Drain Dimension
Operating Range Outdoor Op. Temp. Cooling
Outdoor Op. Temp. Heating
Refrigerant Type
Pipe Sizes (mm)
Refrig Pipe charge
Max Pipe Lgth / (Lift (m) Above, Below)
Power Power Supply
OD unit max current
5
6
1.2-5.8
1.2-6.8
283/233/200/167
50 / 100 / 150
3.82 / 3.80
3.40 / 3.87
39 / 35 / 32 / 29
50 / 33 / -
270 x 900 x 720
750 x 850 x 298
N
35 / 50
815 x 219
805 x 220
R32
30
30 / 20
230 - 240 Volt / 50 Hz / 1 Phase
12
6
7
1.2-6.5
1.2-8.0
283/233/200/167
50 / 100 / 150
3.59 / 3.57
3.71 / 3.69
39 / 35 / 32 / 29
50 / 33 / -
270 x 900 x 720
750 x 850 x 298
N
35 / 50
815 x 219
805 x 220
R32
30
30 / 20
230 - 240 Volt / 50 Hz / 1 Phase
14
7
8
1.5-8.0
1.5-8.5
283/233/200/167
50 / 100 / 150
3.34 / 3.32
3.40 / 3.39
39 / 35 / 32 / 29
50 / 33 / -
270 x 900 x 720
800 x 850 x 298
N
35 / 52
815 x 219
805 x 220
R32
30
30 / 20
230 - 240 Volt / 50 Hz / 1 Phase
16

Documentation

Manuals, brochures and other product literature. If you need any more information, please get in touch.

Model

Model

RAD/RAC-E50YHA RAD/RAC-E60YHA RAD/RAC-E70YHA
Capacity Nominal Cooling kW
Nominal Heating kW
Capacity (Range) Cooling kW
Heating kW
Airflow (Hi/Med/Low/S low) l/sec
External static Pa
Energy Efficiency EER / AEER Cooling
COP / ACOP Heating
Noise Levels (dB(A)) Cooling Indoor Unit Hi/Med/Low/S low
Outdoor Unit Cooling/Heat/ Night
Dimensions (mm) Indoor Unit (WxHxD)
Outdoor Unit (WxHxD)
Indoor unit seperable
Weights (kg) Indoor / Outdoor
Air Spigot/ Drain Dimensions Supply Air (W X H mm)
Return Air (W X H mm)
Drain Dimension
Operating Range Outdoor Op. Temp. Cooling
Outdoor Op. Temp. Heating
Refrigerant Type
Pipe Sizes (mm)
Refrig Pipe charge
Max Pipe Lgth / (Lift (m) Above, Below)
Power Power Supply
OD unit max current
5
6
1.2-5.8
1.2-6.8
283/233/200/167
50 / 100 / 150
3.82 / 3.80
3.40 / 3.87
39 / 35 / 32 / 29
50 / 33 / -
270 x 900 x 720
750 x 850 x 298
N
35 / 50
815 x 219
805 x 220
R32
30
30 / 20
230 - 240 Volt / 50 Hz / 1 Phase
12
6
7
1.2-6.5
1.2-8.0
283/233/200/167
50 / 100 / 150
3.59 / 3.57
3.71 / 3.69
39 / 35 / 32 / 29
50 / 33 / -
270 x 900 x 720
750 x 850 x 298
N
35 / 50
815 x 219
805 x 220
R32
30
30 / 20
230 - 240 Volt / 50 Hz / 1 Phase
14
7
8
1.5-8.0
1.5-8.5
283/233/200/167
50 / 100 / 150
3.34 / 3.32
3.40 / 3.39
39 / 35 / 32 / 29
50 / 33 / -
270 x 900 x 720
800 x 850 x 298
N
35 / 52
815 x 219
805 x 220
R32
30
30 / 20
230 - 240 Volt / 50 Hz / 1 Phase
16