KPI

KPI_header

KPI

Introducing fresher air
KPI_0

01. MAXIMUM FRESH AIR

Choose from three operating modes: free ventilation, automatic ventilation and heat recovery, to maximise air renewal, save energy and improve air conditioning performance.

03. LOW NOISE LEVELS

When you need quieter operation, the sound attenuator reduces noise by up to 5 db(A) compared to standard models.

02. AUTOMATIC CO2 REDUCTION

KPI_2

Model

Model

KPI 252E4E KPI 502E4E KPI 802E4E KPI 1002E4E KPI 1502E4E KPI 2002E4E
Indoor unit power supply
Air flow rate (low-medium-high) m3/h
Static pressure (low-medium-high) Pa
Maximum external static pressure at nominal air flow rate Pa
Type of heat exchanger (material)
Heat exchanger efficiency %
Enthalpy exchanger efficiency in heating %
Enthalpy exchanger efficiency in cooling %
Perceived noise level (low, medium, high) dB(A)
Duct Sizes (dia) mm
Nominal Power Input (high) W
Specific Fan Power (high) W/(m3/s)
Filter class
Maximum external operating temperatures
Remote control (optional)
Dimensions Height mm
Width mm
Depth mm
Weight kg
1~230V 50Hz
250 - 208 - 180
55 - 35 - 30
240
Celluloid
79
66
60
28 / 27 / 25
150
48
408
G3
-20ºC ~ 46 ºC
PC - ARFPE
270
900
750
34
1~230V 50Hz
500 - 420 - 360
80 - 50 - 37
210
Celluloid
78
65
61
33 / 31 / 30
200
117
550
G3
-20ºC ~ 46 ºC
PC - ARFPE
330
1130
920
46
1~230V 50Hz
800 - 650 - 540
90 - 60 - 40
120
Celluloid
78
65
62
35 / 34 / 33
250
243
762
G3
-20ºC ~ 46 ºC
PC - ARFPE
385
1210
1015
51
1~230V 50Hz
1000 - 800 - 620
95 - 65 - 40
190
Celluloid
83
68
62
37 / 34 / 32
300
261
545
-20ºC ~ 46 ºC
PC - ARFPE
385
1600
1295
79
1~230V 50Hz
1500 - 1250 - 950
100 - 70 - 45
200
Celluloid
80
68
62.5
39 / 37 / 35
355
462
836
-20ºC ~ 46 ºC
PC - ARFPE
525
1800
1130
97
1~230V 50Hz
2000 - 1450 - 1200
120 - 65 - 40
170
Celluloid
80
66.5
61.5
40 / 39 / 36
355
666
891
-20ºC ~ 46 ºC
PC - ARFPE
525
1800
1430
106

Documentation

Manuals, brochures and other product literature. If you need any more information, please get in touch.

Model

Model

KPI 252E4E KPI 502E4E KPI 802E4E KPI 1002E4E KPI 1502E4E KPI 2002E4E
Indoor unit power supply
Air flow rate (low-medium-high) m3/h
Static pressure (low-medium-high) Pa
Maximum external static pressure at nominal air flow rate Pa
Type of heat exchanger (material)
Heat exchanger efficiency %
Enthalpy exchanger efficiency in heating %
Enthalpy exchanger efficiency in cooling %
Perceived noise level (low, medium, high) dB(A)
Duct Sizes (dia) mm
Nominal Power Input (high) W
Specific Fan Power (high) W/(m3/s)
Filter class
Maximum external operating temperatures
Remote control (optional)
Dimensions Height mm
Width mm
Depth mm
Weight kg
1~230V 50Hz
250 - 208 - 180
55 - 35 - 30
240
Celluloid
79
66
60
28 / 27 / 25
150
48
408
G3
-20ºC ~ 46 ºC
PC - ARFPE
270
900
750
34
1~230V 50Hz
500 - 420 - 360
80 - 50 - 37
210
Celluloid
78
65
61
33 / 31 / 30
200
117
550
G3
-20ºC ~ 46 ºC
PC - ARFPE
330
1130
920
46
1~230V 50Hz
800 - 650 - 540
90 - 60 - 40
120
Celluloid
78
65
62
35 / 34 / 33
250
243
762
G3
-20ºC ~ 46 ºC
PC - ARFPE
385
1210
1015
51
1~230V 50Hz
1000 - 800 - 620
95 - 65 - 40
190
Celluloid
83
68
62
37 / 34 / 32
300
261
545
-20ºC ~ 46 ºC
PC - ARFPE
385
1600
1295
79
1~230V 50Hz
1500 - 1250 - 950
100 - 70 - 45
200
Celluloid
80
68
62.5
39 / 37 / 35
355
462
836
-20ºC ~ 46 ºC
PC - ARFPE
525
1800
1130
97
1~230V 50Hz
2000 - 1450 - 1200
120 - 65 - 40
170
Celluloid
80
66.5
61.5
40 / 39 / 36
355
666
891
-20ºC ~ 46 ºC
PC - ARFPE
525
1800
1430
106