Commercial Air Conditioning

Our range of commercial is designed to provide small and medium businesses with reliable climate control solutions that excel in comfort and efficiency

Commercial air conditioning systems to create welcoming environments

Whatever your business, comfort is one of the keys to success. Our product range of commercial air conditioners helps to create a welcoming environment in which occupants are comfortable and at ease without increasing running costs.

 

Each business requires a system tailored to its needs. That’s why our commercial HVAC solutions are flexible, from the selection of indoor type and outdoor unit capacity right through to installation possibilities to suit your building and business best. The easy-to-use controllers of our commercial air conditioning systems let you operate and manage your climate, as well as monitor energy usage.

 

The lack of space that many businesses encounter today means that climate control options are often limited. We've solved that issue with a range of compact outdoor units that are reliable and offer design flexibility that means they are easily integrated into all types of spaces and architecture.

 

Smart and compact, our outdoor units use cutting-edge technology combined with performance features like Gentlecool to provide high-performance climate control that is efficient and that can self-diagnose, resulting in more effective maintenance.

 

From retail, restaurants, hotels, commercial offices and more, our commercial air conditioning range is built to deliver adaptable solutions that offer the highest standard of Hitachi Cooling & Heating performance.

"

Accordion Data table proof

Tab 1

Outdoor Unit v2

Outdoor Unit v2

RAS-2WHVNP - Monofásica RAS-2.5WHVNP - Monofásica RAS-3WHVNP - Monofásica RAS-4WHVNPE - Monofásica RAS-5WHVNPE - Monofásica RAS-6WHVNPE - Monofásica RAS-4WHNPE - Trifásica RAS-5WHNPE - Trifásica RAS-6WHNPE - Trifásica RAS-8WHNPE - Trifásica RAS-10WHNPE - Trifásica
Energy class rating 35°C
Power feed
Power consumption Heating 7°C ext. / 30 - 35°C water (1) kW
Cooling 7°C ext. / 30-35°C water (1) kW
Nominal capacity absorbed Heating 7°C ext. / 30 - 35°C water (max) (1) kW
Cooling 7°C ext. / 30-35°C water (1) kW
COP at 7°C ext. / 30-35°C water
EER 35 ° C / 7-12 ° C water
Noise level dB(A)
Airflow m3/h
Diameter of pipes (liquid-gas) pulgadas
Maximum length m
Maximum elevation
Operating ranges ºC (DB)
Refrigerant
Refrigerant charge (max. pipe length with no charge) kg
Compressor
Dimensions Height mm
Width mm
Depth mm
Weight kg
A+++
1 ~230 V 50Hz
2
1.22
14,00 (16,70)
3.8
5.25
3.12
59
2.436
1/4 - 1/2
50
30 / 20
10 ~46 // -15 ~25 / -15 ~35
R410
1,40 (30)
Scroll DC Inverter
600
792
300
43
A+++
1 ~230 V 50Hz
2
1.59
14,00 (16,70)
5
4.8
3.15
60
2.436
1/4 - 1/2
50
30 / 20
10 ~46 // -15 ~25 / -15 ~35
R410
1,50 (30)
Scroll DC Inverter
600
792
300
43
A++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
6
4.55
2.75
61
2.682
3/8 - 5/8
50
30 / 20
10 ~46 // -15 ~25 / -15 ~35
R410
1,70 (40)
Scroll DC Inverter
600
792
300
44
A+++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
7.2
5
3.3
63
4.8
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,30 (60)
Scroll DC Inverter
1.380
950
370
103
A++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
9.5
4.71
3.22
64
5.4
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,40 (60)
Scroll DC Inverter
1.380
950
370
103
A++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
10.5
4.57
2.82
65
6
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
Scroll DC Inverter
1.380
950
370
103
A+++
3N ~400V 50 Hz
2
2.97
14,00 (16,70)
7.2
5
3.3
63
4.8
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,30 (60)
Scroll DC Inverter
1.380
950
370
103
A++
3N ~400V 50 Hz
2
2.95
14,00 (16,70)
9.5
4.71
3.22
64
5.4
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,40 (60)
Scroll DC Inverter
1.380
950
370
103
A++
3N ~400V 50 Hz
2
3.72
14,00 (16,70)
10.5
4.57
2.82
65
6
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
Scroll DC Inverter
1.380
950
370
103
A++
3N ~400V 50 Hz
2
Pendiente
14,00 (16,70)
Pendiente
4.3
Pendiente
71
7.62
8/3/2001
70
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
5
Scroll DC Inverter
1.380
950
370
137
A+
3N ~400V 50 Hz
2
Pendiente
14,00 (16,70)
Pendiente
4.3
Pendiente
72
8.04
2/1/2001
70
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
5.3
Scroll DC Inverter
1.380
950
370
139

Outdoor Unit v2

Outdoor Unit v2

RAS-2WHVNP - Monofásica RAS-2.5WHVNP - Monofásica RAS-3WHVNP - Monofásica RAS-4WHVNPE - Monofásica RAS-5WHVNPE - Monofásica RAS-6WHVNPE - Monofásica RAS-4WHNPE - Trifásica RAS-5WHNPE - Trifásica RAS-6WHNPE - Trifásica RAS-8WHNPE - Trifásica RAS-10WHNPE - Trifásica
Energy class rating 35°C
Power feed
Power consumption Heating 7°C ext. / 30 - 35°C water (1) kW
Cooling 7°C ext. / 30-35°C water (1) kW
Nominal capacity absorbed Heating 7°C ext. / 30 - 35°C water (max) (1) kW
Cooling 7°C ext. / 30-35°C water (1) kW
COP at 7°C ext. / 30-35°C water
EER 35 ° C / 7-12 ° C water
Noise level dB(A)
Airflow m3/h
Diameter of pipes (liquid-gas) pulgadas
Maximum length m
Maximum elevation
Operating ranges ºC (DB)
Refrigerant
Refrigerant charge (max. pipe length with no charge) kg
Compressor
Dimensions Height mm
Width mm
Depth mm
Weight kg
A+++
1 ~230 V 50Hz
2
1.22
14,00 (16,70)
3.8
5.25
3.12
59
2.436
1/4 - 1/2
50
30 / 20
10 ~46 // -15 ~25 / -15 ~35
R410
1,40 (30)
Scroll DC Inverter
600
792
300
43
A+++
1 ~230 V 50Hz
2
1.59
14,00 (16,70)
5
4.8
3.15
60
2.436
1/4 - 1/2
50
30 / 20
10 ~46 // -15 ~25 / -15 ~35
R410
1,50 (30)
Scroll DC Inverter
600
792
300
43
A++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
6
4.55
2.75
61
2.682
3/8 - 5/8
50
30 / 20
10 ~46 // -15 ~25 / -15 ~35
R410
1,70 (40)
Scroll DC Inverter
600
792
300
44
A+++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
7.2
5
3.3
63
4.8
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,30 (60)
Scroll DC Inverter
1.380
950
370
103
A++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
9.5
4.71
3.22
64
5.4
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,40 (60)
Scroll DC Inverter
1.380
950
370
103
A++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
10.5
4.57
2.82
65
6
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
Scroll DC Inverter
1.380
950
370
103
A+++
3N ~400V 50 Hz
2
2.97
14,00 (16,70)
7.2
5
3.3
63
4.8
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,30 (60)
Scroll DC Inverter
1.380
950
370
103
A++
3N ~400V 50 Hz
2
2.95
14,00 (16,70)
9.5
4.71
3.22
64
5.4
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,40 (60)
Scroll DC Inverter
1.380
950
370
103
A++
3N ~400V 50 Hz
2
3.72
14,00 (16,70)
10.5
4.57
2.82
65
6
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
Scroll DC Inverter
1.380
950
370
103
A++
3N ~400V 50 Hz
2
Pendiente
14,00 (16,70)
Pendiente
4.3
Pendiente
71
7.62
8/3/2001
70
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
5
Scroll DC Inverter
1.380
950
370
137
A+
3N ~400V 50 Hz
2
Pendiente
14,00 (16,70)
Pendiente
4.3
Pendiente
72
8.04
2/1/2001
70
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
5.3
Scroll DC Inverter
1.380
950
370
139

Tab 2

title

title

Tab 3 - Data table proof 2062023

Outdoor Unit v2

Outdoor Unit v2

RAS-2WHVNP - Monofásica RAS-2.5WHVNP - Monofásica RAS-3WHVNP - Monofásica RAS-4WHVNPE - Monofásica RAS-5WHVNPE - Monofásica RAS-6WHVNPE - Monofásica RAS-4WHNPE - Trifásica RAS-5WHNPE - Trifásica RAS-6WHNPE - Trifásica RAS-8WHNPE - Trifásica RAS-10WHNPE - Trifásica
Energy class rating 35°C
Power feed
Power consumption Heating 7°C ext. / 30 - 35°C water (1) kW
Cooling 7°C ext. / 30-35°C water (1) kW
Nominal capacity absorbed Heating 7°C ext. / 30 - 35°C water (max) (1) kW
Cooling 7°C ext. / 30-35°C water (1) kW
COP at 7°C ext. / 30-35°C water
EER 35 ° C / 7-12 ° C water
Noise level dB(A)
Airflow m3/h
Diameter of pipes (liquid-gas) pulgadas
Maximum length m
Maximum elevation
Operating ranges ºC (DB)
Refrigerant
Refrigerant charge (max. pipe length with no charge) kg
Compressor
Dimensions Height mm
Width mm
Depth mm
Weight kg
A+++
1 ~230 V 50Hz
2
1.22
14,00 (16,70)
3.8
5.25
3.12
59
2.436
1/4 - 1/2
50
30 / 20
10 ~46 // -15 ~25 / -15 ~35
R410
1,40 (30)
Scroll DC Inverter
600
792
300
43
A+++
1 ~230 V 50Hz
2
1.59
14,00 (16,70)
5
4.8
3.15
60
2.436
1/4 - 1/2
50
30 / 20
10 ~46 // -15 ~25 / -15 ~35
R410
1,50 (30)
Scroll DC Inverter
600
792
300
43
A++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
6
4.55
2.75
61
2.682
3/8 - 5/8
50
30 / 20
10 ~46 // -15 ~25 / -15 ~35
R410
1,70 (40)
Scroll DC Inverter
600
792
300
44
A+++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
7.2
5
3.3
63
4.8
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,30 (60)
Scroll DC Inverter
1.380
950
370
103
A++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
9.5
4.71
3.22
64
5.4
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,40 (60)
Scroll DC Inverter
1.380
950
370
103
A++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
10.5
4.57
2.82
65
6
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
Scroll DC Inverter
1.380
950
370
103
A+++
3N ~400V 50 Hz
2
2.97
14,00 (16,70)
7.2
5
3.3
63
4.8
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,30 (60)
Scroll DC Inverter
1.380
950
370
103
A++
3N ~400V 50 Hz
2
2.95
14,00 (16,70)
9.5
4.71
3.22
64
5.4
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,40 (60)
Scroll DC Inverter
1.380
950
370
103
A++
3N ~400V 50 Hz
2
3.72
14,00 (16,70)
10.5
4.57
2.82
65
6
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
Scroll DC Inverter
1.380
950
370
103
A++
3N ~400V 50 Hz
2
Pendiente
14,00 (16,70)
Pendiente
4.3
Pendiente
71
7.62
8/3/2001
70
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
5
Scroll DC Inverter
1.380
950
370
137
A+
3N ~400V 50 Hz
2
Pendiente
14,00 (16,70)
Pendiente
4.3
Pendiente
72
8.04
2/1/2001
70
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
5.3
Scroll DC Inverter
1.380
950
370
139

Data table multiple

Outdoor Unit v2

Outdoor Unit v2

RAS-2WHVNP - Monofásica RAS-2.5WHVNP - Monofásica RAS-3WHVNP - Monofásica RAS-4WHVNPE - Monofásica RAS-5WHVNPE - Monofásica RAS-6WHVNPE - Monofásica RAS-4WHNPE - Trifásica RAS-5WHNPE - Trifásica RAS-6WHNPE - Trifásica RAS-8WHNPE - Trifásica RAS-10WHNPE - Trifásica
Energy class rating 35°C
Power feed
Power consumption Heating 7°C ext. / 30 - 35°C water (1) kW
Cooling 7°C ext. / 30-35°C water (1) kW
Nominal capacity absorbed Heating 7°C ext. / 30 - 35°C water (max) (1) kW
Cooling 7°C ext. / 30-35°C water (1) kW
COP at 7°C ext. / 30-35°C water
EER 35 ° C / 7-12 ° C water
Noise level dB(A)
Airflow m3/h
Diameter of pipes (liquid-gas) pulgadas
Maximum length m
Maximum elevation
Operating ranges ºC (DB)
Refrigerant
Refrigerant charge (max. pipe length with no charge) kg
Compressor
Dimensions Height mm
Width mm
Depth mm
Weight kg
A+++
1 ~230 V 50Hz
2
1.22
14,00 (16,70)
3.8
5.25
3.12
59
2.436
1/4 - 1/2
50
30 / 20
10 ~46 // -15 ~25 / -15 ~35
R410
1,40 (30)
Scroll DC Inverter
600
792
300
43
A+++
1 ~230 V 50Hz
2
1.59
14,00 (16,70)
5
4.8
3.15
60
2.436
1/4 - 1/2
50
30 / 20
10 ~46 // -15 ~25 / -15 ~35
R410
1,50 (30)
Scroll DC Inverter
600
792
300
43
A++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
6
4.55
2.75
61
2.682
3/8 - 5/8
50
30 / 20
10 ~46 // -15 ~25 / -15 ~35
R410
1,70 (40)
Scroll DC Inverter
600
792
300
44
A+++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
7.2
5
3.3
63
4.8
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,30 (60)
Scroll DC Inverter
1.380
950
370
103
A++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
9.5
4.71
3.22
64
5.4
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,40 (60)
Scroll DC Inverter
1.380
950
370
103
A++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
10.5
4.57
2.82
65
6
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
Scroll DC Inverter
1.380
950
370
103
A+++
3N ~400V 50 Hz
2
2.97
14,00 (16,70)
7.2
5
3.3
63
4.8
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,30 (60)
Scroll DC Inverter
1.380
950
370
103
A++
3N ~400V 50 Hz
2
2.95
14,00 (16,70)
9.5
4.71
3.22
64
5.4
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,40 (60)
Scroll DC Inverter
1.380
950
370
103
A++
3N ~400V 50 Hz
2
3.72
14,00 (16,70)
10.5
4.57
2.82
65
6
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
Scroll DC Inverter
1.380
950
370
103
A++
3N ~400V 50 Hz
2
Pendiente
14,00 (16,70)
Pendiente
4.3
Pendiente
71
7.62
8/3/2001
70
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
5
Scroll DC Inverter
1.380
950
370
137
A+
3N ~400V 50 Hz
2
Pendiente
14,00 (16,70)
Pendiente
4.3
Pendiente
72
8.04
2/1/2001
70
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
5.3
Scroll DC Inverter
1.380
950
370
139

Data table multiple

Outdoor Unit v2

Outdoor Unit v2

RAS-2WHVNP - Monofásica RAS-2.5WHVNP - Monofásica RAS-3WHVNP - Monofásica RAS-4WHVNPE - Monofásica RAS-5WHVNPE - Monofásica RAS-6WHVNPE - Monofásica RAS-4WHNPE - Trifásica RAS-5WHNPE - Trifásica RAS-6WHNPE - Trifásica RAS-8WHNPE - Trifásica RAS-10WHNPE - Trifásica
Energy class rating 35°C
Power feed
Power consumption Heating 7°C ext. / 30 - 35°C water (1) kW
Cooling 7°C ext. / 30-35°C water (1) kW
Nominal capacity absorbed Heating 7°C ext. / 30 - 35°C water (max) (1) kW
Cooling 7°C ext. / 30-35°C water (1) kW
COP at 7°C ext. / 30-35°C water
EER 35 ° C / 7-12 ° C water
Noise level dB(A)
Airflow m3/h
Diameter of pipes (liquid-gas) pulgadas
Maximum length m
Maximum elevation
Operating ranges ºC (DB)
Refrigerant
Refrigerant charge (max. pipe length with no charge) kg
Compressor
Dimensions Height mm
Width mm
Depth mm
Weight kg
A+++
1 ~230 V 50Hz
2
1.22
14,00 (16,70)
3.8
5.25
3.12
59
2.436
1/4 - 1/2
50
30 / 20
10 ~46 // -15 ~25 / -15 ~35
R410
1,40 (30)
Scroll DC Inverter
600
792
300
43
A+++
1 ~230 V 50Hz
2
1.59
14,00 (16,70)
5
4.8
3.15
60
2.436
1/4 - 1/2
50
30 / 20
10 ~46 // -15 ~25 / -15 ~35
R410
1,50 (30)
Scroll DC Inverter
600
792
300
43
A++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
6
4.55
2.75
61
2.682
3/8 - 5/8
50
30 / 20
10 ~46 // -15 ~25 / -15 ~35
R410
1,70 (40)
Scroll DC Inverter
600
792
300
44
A+++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
7.2
5
3.3
63
4.8
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,30 (60)
Scroll DC Inverter
1.380
950
370
103
A++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
9.5
4.71
3.22
64
5.4
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,40 (60)
Scroll DC Inverter
1.380
950
370
103
A++
1 ~230 V 50Hz
2
2.97
14,00 (16,70)
10.5
4.57
2.82
65
6
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
Scroll DC Inverter
1.380
950
370
103
A+++
3N ~400V 50 Hz
2
2.97
14,00 (16,70)
7.2
5
3.3
63
4.8
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,30 (60)
Scroll DC Inverter
1.380
950
370
103
A++
3N ~400V 50 Hz
2
2.95
14,00 (16,70)
9.5
4.71
3.22
64
5.4
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
3,40 (60)
Scroll DC Inverter
1.380
950
370
103
A++
3N ~400V 50 Hz
2
3.72
14,00 (16,70)
10.5
4.57
2.82
65
6
3/8 - 5/8
75
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
Scroll DC Inverter
1.380
950
370
103
A++
3N ~400V 50 Hz
2
Pendiente
14,00 (16,70)
Pendiente
4.3
Pendiente
71
7.62
8/3/2001
70
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
5
Scroll DC Inverter
1.380
950
370
137
A+
3N ~400V 50 Hz
2
Pendiente
14,00 (16,70)
Pendiente
4.3
Pendiente
72
8.04
2/1/2001
70
30 / 20
10 ~46 // -25 ~25 / -25 ~35
R410
5.3
Scroll DC Inverter
1.380
950
370
139

Data table multiple

Find your Hitachi Cooling & Heating air conditioning unit

Hitachi HVAC for Commercial Spaces

With over 80 years of experience, we are confident that our range of commercial HVAC solutions provides small and medium businesses with the leading climate control technology to create and maintain the perfect indoor environment. Meeting the evolving requirements of our clients means that we are constantly innovating our systems, resulting in a collection of elegant and efficient commercial AC options that are designed to adapt to you and the spaces that they inhabit. We cater for all types of projects and offer an extensive range of solutions so that you can find the system right for the job.

 

To see more of our ranges and solutions, click here , and if you are interested in receiving more information from a professional installer, find your nearest one using our Partner Locator.

airCloud Go maintenance issues – offline units and Google Play
Read more
Hitachi Cooling & Heating products are manufactured and sold by Bosch Home Comfort Group.
Read more
airCloud Go maintenance issues

Dear airCloud Go users,  

We apologize as the app is experiencing technical issues due to recent updates. 

1. If your Hitachi unit appears offline on your app 
We recommend turning off your Hitachi unit and switching it back on. Repeat a few times if necessary, it should reconnect your Hitachi unit to airCloud Go.  
You don’t need to delete and re-install the app or try pairing your Hitachi unit again. 
NOTE: Power off/on means disconnecting and reconnecting the electric power supply to the unit, not only turn off with the remote control. To switch off you can use your electric board switch. 
 
2. If your Hitachi unit appears offline for Google Home voice command 
 We are currently working on a fix for that issue. In the meantime we recommend using the airCloud Go app or the physical remote control of the Hitachi air conditioner. 
 
We apologize for any inconvenience and appreciate your patience.