UTOPIA IVX COMFORT_header

UTOPIA IVX COMFORT

Climate control for small to medium-sized businesses
UTOPIA IVX COMFORT_0

01. FOR UP TO 4 SPACES

The system provides independent temperature control for up to four separate spaces, making it the ideal climate control solution for small to medium businesses.

02. COMBINE DIFFERENT UNITS

UTOPIA IVX COMFORT_1

03. CENTRALISED CONTROL

Compatible with H-Link II communication bus to integrate air curtains, and with the CSNET Web interface, which provides centralised control over system operation. The control unit enables energy consumption to be kept in hand, thanks to its automatic control over energy demand. In addition, the unit is compatible with the H-Link II communication bus to integrate air curtains, and with the CSNET Web interface, which provides remote control over system operation.


 


(New Glossary term (test PHP))

UTOPIA IVX COMFORT_3

04. HIGH PERFORMANCE, LOW ENERGY

The whole range achieves high seasonal performance at partial loads, the most common operating environment when outside temperatures are not extreme.
UTOPIA IVX COMFORT_4_0
UTOPIA IVX COMFORT_4_1
UTOPIA IVX COMFORT_4_2
UTOPIA IVX COMFORT_4_3
UTOPIA IVX COMFORT_4_4
1/5

Model

Model

RAS-3HVNC1 RAS-4HVNC1E RAS-5HVNC1E RAS-6HVNC1E RAS-4HNC1E RAS-5HNC1E RAS-6HNC1E RAS-8HNCE RAS-10HNCE RAS-12HNC
Power feed
Min-Max Number of Indoor Units
Connection Ratio
Nominal Capacity (min-max) Cooling kW
Heating kW
Power consumption Cooling kW
Heating kW
EER / COP
SEER / SCOP (energy labels)
Perceived noise level (night mode) dB(A)
Air flow m³/h
Diameter of pipes (liquid-gas) Inches
Maximum length m
Maximum elevation m
Refrigerant charge (pre-charged pipe length) kg(m)
Additional refrigerant charge g/m
Refrigerant
Compressor
Dimensions Height mm
Width mm
Depth mm
Weight Kg
* See Technical Catalogue for Restrictions
1~230v50H
1-2*
90-110%
7,10 (3,20-8,00)
8,00 (3,50-10,60)
2,26
2,00
3,14 / 4,00
6,00 / 4,21 (A+ / A+)
48 (46)
2682
(3/8)-(5/8)
50
30
1,9 (20)
40
R410A
SCROLL
600
792
300
44
1~230v50H
1-4*
90-115%
10,00 (4,50-11,20)
11,20 (5,00-14,00)
2,70
2,45
3,70 / 4,57
6,57 / 4,47 (A++ / A+)
52 (50)
3720
(3/8)-(5/8)
70
30
3,2 (30)
40
R410A
SCROLL
1140
950
370
79
1~230v50H
1-4*
90-115%
12,50 (5,70-14,00)
14,00 (6,00-16,00)
3,71
3,60
3,37 /3,89
6,89 / 4,38
52 (50)
4080
(3/8)-(5/8)
75
30
3,2 (30)
60
R410A
SCROLL
1140
950
370
89
1~230v50H
1-4*
90-115%
14,00 (6,00-16,00)
16,00 (5,00-20,00)
4,29
4,49
3,26 / 3,56
6,46 / 4,38
55 (53)
4800
(3/8)-(5/8)
75
30
3,2 (30)
60
R410A
SCROLL
1140
950
370
89
3N~ 400 V 50 Hz
1-4*
90-115%
10,00 (4,50 -11,20)
11,20 (5,00-14,00)
2,70
2,45
3,70 / 4,57
6,41 / 4,47 (A++ / A+)
52 (50)
3720
(3/8) - (5/8)
70
30
3,2 (30)
40
R410A
SCROLL
1140
950
370
79
3N~ 400 V 50 Hz
1-4*
90-115%
12,50 (5,70-14,00)
14,00 (6,00-16,00)
3,71
3,60
3,37 / 3,89
6,83 / 4,38
52 (50)
4080
(3/8) - (5/8)
75
30
3,2 (30)
60
R410A
SCROLL
1140
950
370
89
3N~ 400 V 50 Hz
1-4*
90-115%
14,00 (6,00 -16,00)
16,00 (5,00-20,00)
4,29
4,49
3,26 / 3,56
6,42 / 4,38
55 (53)
4800
(3/8) - (5/8)
75
30
3,2 (30)
60
R410A
SCROLL
1140
950
370
89
3N~ 400 V 50 Hz
1-4*
90-115%
20,00 (9,00 - 22,40)
22,40 (8,30 - 25,00)
5,95
5,88
3,36 / 3,81
6,79 / 4,19
57 (55)
7620
(3/8) - (1 1/8)
100
30
5,7 (30)
See TC
R410A
SCROLL
1380
950
370
136
3N~ 400 V 50 Hz
1-4*
90-115%
25,00 (10,00 - 28,00)
28,00 (8,00 - 35,00)
8.23
7.71
3,02 / 3,63
6,61 / 3,79
58 (56)
8040
(1/2) - (1 1/8)
100
30
6,2 (30)
See TC
R410A
SCROLL
1380
950
370
138
3N~ 400 V 50 Hz
1-4*
90-115%
30,00 (11,20 - 33,50)
33,50 (9,00 - 37,50)
11,67
9,46
2,57 / 3,54
5,30 / 3,66
59 (56)
9780
(1/2) - (1 1/8)
100
30
6,7 (30)
See TC
R410A
SCROLL
1650
1100
390
168

Indoor Units

Model

Model

RAS-3HVNC1 RAS-4HVNC1E RAS-5HVNC1E RAS-6HVNC1E RAS-4HNC1E RAS-5HNC1E RAS-6HNC1E RAS-8HNCE RAS-10HNCE RAS-12HNC
Power feed
Min-Max Number of Indoor Units
Connection Ratio
Nominal Capacity (min-max) Cooling kW
Heating kW
Power consumption Cooling kW
Heating kW
EER / COP
SEER / SCOP (energy labels)
Perceived noise level (night mode) dB(A)
Air flow m³/h
Diameter of pipes (liquid-gas) Inches
Maximum length m
Maximum elevation m
Refrigerant charge (pre-charged pipe length) kg(m)
Additional refrigerant charge g/m
Refrigerant
Compressor
Dimensions Height mm
Width mm
Depth mm
Weight Kg
* See Technical Catalogue for Restrictions
1~230v50H
1-2*
90-110%
7,10 (3,20-8,00)
8,00 (3,50-10,60)
2,26
2,00
3,14 / 4,00
6,00 / 4,21 (A+ / A+)
48 (46)
2682
(3/8)-(5/8)
50
30
1,9 (20)
40
R410A
SCROLL
600
792
300
44
1~230v50H
1-4*
90-115%
10,00 (4,50-11,20)
11,20 (5,00-14,00)
2,70
2,45
3,70 / 4,57
6,57 / 4,47 (A++ / A+)
52 (50)
3720
(3/8)-(5/8)
70
30
3,2 (30)
40
R410A
SCROLL
1140
950
370
79
1~230v50H
1-4*
90-115%
12,50 (5,70-14,00)
14,00 (6,00-16,00)
3,71
3,60
3,37 /3,89
6,89 / 4,38
52 (50)
4080
(3/8)-(5/8)
75
30
3,2 (30)
60
R410A
SCROLL
1140
950
370
89
1~230v50H
1-4*
90-115%
14,00 (6,00-16,00)
16,00 (5,00-20,00)
4,29
4,49
3,26 / 3,56
6,46 / 4,38
55 (53)
4800
(3/8)-(5/8)
75
30
3,2 (30)
60
R410A
SCROLL
1140
950
370
89
3N~ 400 V 50 Hz
1-4*
90-115%
10,00 (4,50 -11,20)
11,20 (5,00-14,00)
2,70
2,45
3,70 / 4,57
6,41 / 4,47 (A++ / A+)
52 (50)
3720
(3/8) - (5/8)
70
30
3,2 (30)
40
R410A
SCROLL
1140
950
370
79
3N~ 400 V 50 Hz
1-4*
90-115%
12,50 (5,70-14,00)
14,00 (6,00-16,00)
3,71
3,60
3,37 / 3,89
6,83 / 4,38
52 (50)
4080
(3/8) - (5/8)
75
30
3,2 (30)
60
R410A
SCROLL
1140
950
370
89
3N~ 400 V 50 Hz
1-4*
90-115%
14,00 (6,00 -16,00)
16,00 (5,00-20,00)
4,29
4,49
3,26 / 3,56
6,42 / 4,38
55 (53)
4800
(3/8) - (5/8)
75
30
3,2 (30)
60
R410A
SCROLL
1140
950
370
89
3N~ 400 V 50 Hz
1-4*
90-115%
20,00 (9,00 - 22,40)
22,40 (8,30 - 25,00)
5,95
5,88
3,36 / 3,81
6,79 / 4,19
57 (55)
7620
(3/8) - (1 1/8)
100
30
5,7 (30)
See TC
R410A
SCROLL
1380
950
370
136
3N~ 400 V 50 Hz
1-4*
90-115%
25,00 (10,00 - 28,00)
28,00 (8,00 - 35,00)
8.23
7.71
3,02 / 3,63
6,61 / 3,79
58 (56)
8040
(1/2) - (1 1/8)
100
30
6,2 (30)
See TC
R410A
SCROLL
1380
950
370
138
3N~ 400 V 50 Hz
1-4*
90-115%
30,00 (11,20 - 33,50)
33,50 (9,00 - 37,50)
11,67
9,46
2,57 / 3,54
5,30 / 3,66
59 (56)
9780
(1/2) - (1 1/8)
100
30
6,7 (30)
See TC
R410A
SCROLL
1650
1100
390
168

Indoor Units

airCloud Go maintenance issues – offline units and Google Play
Read more
Hitachi Cooling & Heating products are manufactured and sold by Bosch Home Comfort Group.
Read more
airCloud Go maintenance issues

Dear airCloud Go users,  

We apologize as the app is experiencing technical issues due to recent updates. 

1. If your Hitachi unit appears offline on your app 
We recommend turning off your Hitachi unit and switching it back on. Repeat a few times if necessary, it should reconnect your Hitachi unit to airCloud Go.  
You don’t need to delete and re-install the app or try pairing your Hitachi unit again. 
NOTE: Power off/on means disconnecting and reconnecting the electric power supply to the unit, not only turn off with the remote control. To switch off you can use your electric board switch. 
 
2. If your Hitachi unit appears offline for Google Home voice command 
 We are currently working on a fix for that issue. In the meantime we recommend using the airCloud Go app or the physical remote control of the Hitachi air conditioner. 
 
We apologize for any inconvenience and appreciate your patience.